Miniature Circuit Breakers
UL508 Listed
Manual Motor Controllers
- Suitable for Motor Disconnect Means
- CSA C22.2 No. 14 Certified
- 10kA Interrupt Rating
- Electrical Ratings up to 60A/480VAC
- Thermal Magnetic Type
- Horsepower Rated for Motor Applications
- 6 Different Trip Characteristics
- Available in 1, 2, 3 Pole and 1 or 3 Pole + Neutral
|

|
|
|
MA/USA Three Phase Adjustable Circuit Breakers
UL Listed MA/USA Manual Motor Controller, group rated for direct applications under NEC 430-53.
- Adjustable Operating Current Up to 100% of Rated Current, 0.1A to 40A in 15 Rated Currents
- Thermal Overload Protection Satisfies NEC 430-32 and NEMA MG1-1993
- High Fixed Magnetic Trip for High In-Rush Applications
- Half-Cycle Break-and-Clear (Current and Energy Limiting)
- 3 AWG Terminals Allow Larger, High Current Groups (40A Maximum Single load), Factory and Field Wiring
- High Short-Circuit Interrupt Capacity
- 480Y/277VAC Maximum
|

|
|
|
|
|
FI Earth Leakage Circuit Breakers
Compact DIN rail mount FI Earth Leakage Circuit Breakers detect and interrupt ground faults. They are VDE approved for the European system of protecting people, animals, equipment and property from dangerous line-to-ground and shock hazard currents.
US applications include ground fault protection of equipment (GFPE), especially when high distributed capacitance or other leakages cause excessive nuisance trips at lower fault currents.
- FI Four Pole, 2- or 3-Phase
- FI Two Pole, Single Phase
- Trip Capable on Decayed Line Voltage
- Marked Approval of VDE
- Marked "Snowflake" Temperature Range (-25 to 40 °C [-13 to 104 °F])
- Marked Trip Sensitivity to Pulsed as well as Sinusoidal Fault Currents
- Integral Test Circuit
- Insensitive to Vibration, etc
|

|
|
|
|
|
V-EA and MA Accessories
Expand control and monitoring capabilities.
- Auxiliary Contact
- Undervoltage Trip
- Shunt Trip
- Cooling Spacer
- Lock-Outs
- Touch Protectors
- Busbar systems
|
 |
|
|